New VPKUBIF Thick 20 Amp 1/2 in. Home Maintenance. Picture Information. Move over photo to zoom. [Click to enlarge any image]. However, not all Sylvania and GTE-Slyvania branded panels are dangerous. Open the electrical panel, remove the panel face, pull one representative circuit breaker, and compare the side of that breaker as well as the electrical panel bus-bars to which the breaker connects to those in this photo. Details marked by yellow arrows indicate that is not a Zinsco-design electrical panel, bus, nor breaker. The panel may have been there for 30 years and seem to work fine, however, the underlying problems are there and it’s simply not worth the risk. Then we can look for the characteristic red or blue toggle switched breakers that are one of the indicators of Zinsco-Sylvania versions (that are unsafe).2. A small white label with dark blue writing identifies it as GTE Sylvania 390-205-09. The first time I tried to remove Zinsco circuit breakers from a panel box, every circuit breaker in the panel box was tack welded to the power bus. Another panel earlier this year was also of the same panel design, and GTE-Sylvania markings but without the Zinsco labels or markings on anything but one breaker inside. The cost to replace a Federal Pacific or Zinsco panel ranges from $1,500 to $4,000. IF NOT (which I think is the case for your panel) you have a different panel design for which we don't have the same failure rate data nor reports. Zinsco electric panels could leave property owners at risk for both fire and electric shock as a result of failing to operate properly as much as 25% of the time. On 2019-12-16 by (mod) - How can I determine if my sylvania 390 250 09 main panel is 100 amp or 125 amp? Sorry. This was a good thing but when the shortage came many were redesigned with anodized aluminum. Square D QO Panel Deadfront Cover With Door 24 Space. I can't tell. I tagged along with the inspector and he told me the house (1973 build) had a Zinsco panel and aluminum wiring. On 2019-10-16 by (mod) - which way is the "OFF" position on this Sylvania electrical panel? Power & Electrical Supplies .. Enclosed [above] is a pic of my Electrical Box but does not show that it’s a GTE Zinsco which are having to be replaced. we tried search Sylvania, and Cutler, and Westinghouse, but none of the panels look anything like ours. You're welcome to print this page along with our conversation to share with the other parties involved. Do any panels from this time frame have the "Zinsco breaker/panel" problem? Another infamous models to look out for are the Zinsco and Challenger electrical panels, … - to know the age of the home I don't want to generate a fight with your home inspector but it appears to me the inspector is mistaken. This Sylvania electrical panel, NOT a Zinsco design, was found in a home in Arizona. The company is now defunct, but some homes built in the 70's still have these unsafe panels. you have the poor-performing breakers that we describe. 1320 Dayton Street SE, Olympia, WA 98501, 360-705-4225, Fax 360-705-0130 or by email to, Thanks to various electricians, home owners, and home inspectors for contributing the Zinsco Sylvania-Zinsco electric panel and circuit breaker, Thanks to Joe Funderburk, GarthSee the electric panel ampacity determination steps given atELECTRICAL PANEL AMPACITY First thing I have to say is that you should really consider a panel upgrade as soon as possible. Else I can but guess that you're asking if this is one of the problematic Zinsco-Sylvania panel models. 1-Pole Federal Pacific Stab-Lok Type NA Replacement Circuit Breaker Connecticut Electric manufactures new high Connecticut Electric manufactures new high quality replacement circuit breakers for Stab-Lok load centers that accept NA style circuit breakers. Well, maybe not. Watch out: do NOT try to open up your panel nor to remove circuit breakers yourself. The biggest cost for most electrical work is labor. This diagram illustrates some of the most common circuits found in a typical 200 amp circuit breaker service panel box. Anyways, here's a picture of the panel. Panel Below is a picture of a Federal Pacific Electric panel. It was a very popular product and installed throughout North America. Saved by Absolute Inspection Services, LLC. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. (Zinsco electrical panel photo below) 3. The panel label also gives some restrictions on number and types of circuit breakers that could be installed. You might also want to see our article series starting at BACKUP ELECTRICAL GENERATORS. Now my water heater and drier doesn't seem to be working. > can't reset breaker > posts picture of Zinsco panel – Harper - Reinstate Monica Dec 11 '18 at 16:00. Mar 6, 2020 - This is a picture of a melted Zinsco breaker. This is a picture of a Zinsco panel. Mar 6, 2020 - This is a picture of a melted Zinsco breaker. Saved from absoluteid.net. IF the bus and breaker in your panel match these - a vertical or thin on-edge strip bus and those deep slot connectors in the circuit breaker. In my picture, it's clearly a line tap that isn't protected by the breaker. we recently bought a home with a Sylvania panel. Best wishes, thanks for asking about this, and do let me know if you have success. Thanks to our wide inventory of Zinsco … The Connecticut Electric 125-Amp Type RBK UBI Replacement Buss Bar Kit for Zinsco Load Centers features 2 copper-plated buss bars. Don't remove the cover that is don't expose the panel interior because you could get shocked. Zinsco or Sylvania panel cover. Your label does not include those terms and all of your circuit breakers are black. They don't have the characteristic deep narrow slot that you see in other Zinsco photos including one just below your own posting.The identification of the problematic Zinsco breaker design can be difficult if the inspector can't see inside the panel (inspection standards generally expect the inspector to remove the cover and inspect the interior as long as he feels safe doing so) - since Zinsco design breakers were installed in panels bearing the namesZinsco, GTE-Sylvania $29.99 + $4.99 shipping. Is this panel of yours a standalone breaker panel with the meter somewhere else, or a meter main device with the meter socket in the same box as the panel, by the way? At this point, the panel is not able to be shut off manually and power is continuing to be supplied to the panel until the service can be terminated or wires melted. Move over photo to zoom. This is a picture of a Zinsco panel. Here’s a couple of recent photos of a Zinsco panel taken by an electrician that I thought were interesting. $29.99 + $4.99 shipping. - anonymous by private email 2018/05/02. However a home inspector is obligated to point out life safety hazards (as well as other property conditions) that she or he observed - something that would protect everyone involved. The following picture is of a typical split bus panel with its dead-front cover in place. These panels have a reputation for being problematic and further evaluation by a qualified electrician is recommended. Eaton’s CH 3/4-inch load centers enclose CH circuit breakers for power distribution and circuit protection in residential and light commercial applications. Melted Zinsco Breaker. Our conversation and more detail is now at INTERLOCK KITS for BACKUP GENERATORS The breakers are installed in a panel so that contact is made with one of two hot bus bars running down the middle of the box. Zinsco electric panels could leave property owners at risk for both fire and electric shock as a result of failing to operate properly as much as 25% of the time. Another panel earlier this year was also of the same panel design, and GTE-Sylvania markings but without the Zinsco labels or markings on anything but one breaker inside. Below: The photo shows a classic Zinsco-Sylvania circuit breaker design. THEN She ... Zinsco Panel Box Problems with certain Zinsco panels cannot be seen by the naked eye. Sylvania, non-Zinsco circuit breaker & electrical panel identification guide: Here we provide text, labels, and equipment photographs used to help identify Sylvania electrical panels and circuit breakers. A malfunctioning Zinsco system can … Electrical Panel Breaker Box Failure In Delray Beach Florida. The greatest reason being, the safety standards that were acceptable in the 60’s and 70’s are much more stringent today and would never be approved for use. If you suspect that you may have a Federal Pacific Electric, Zinsco, or an outdated circuit breaker panel in your home, or in any event, you have not had your panel inspected recently, you owe it to yourself and your family to contact a licensed electrical contractor in your area for an inspection. They have design flaws that could cause a house fire. We understand that hard-to-find and obsolete breakers and hardware can create a frustrating obstacle when it comes to getting your electrical system up and running. [DF NOTE: I do NOT recommend this obsolete publication, though it was cited in the original. 4-77 1977 [Lots of sketches of older-type service panels.]. Could you please send me a photo of the electrical box entirely from its outside front, and a photo showing a close up of the circuit breakers themselves. Are all Zinsco panels and circuit breakers under suspicion of failure? . "Electrical Systems," A Training Manual for Home Inspectors, Alfred L. Alk, American Society of Home Inspectors (ASHI), 1987, available from ASHI. For a more detailed look at these issues and this product, click here. Electrical panel replacement typically takes 8 to 10 hours which includes 200-amp capability, a new panel with main breaker and ten circuit breakers, labor, and all required materials. Normal recommendation is to replace Zinsco panels as they have a reputation for breakers not tripping and instead starting fires. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. The following picture is of a typical split bus panel with its dead-front cover in place. "Evaluating Wiring in Older Minnesota Homes," Agricultural Extension Service, University of Minnesota, St. Paul, Minnesota 55108. 130.96 KB. This entry was posted in Florida Home Owners Insurance , Homeowners Insurance and tagged Federal Pacific Electrical , fire hazard , panel by jerry . GuDoesn't look like it -The unequivocal details would be Zinsco appearing in a label ORthis breaker and bus design (as shown in the article above) IMAGE LOST by older version of Clark Van Oyen’s useful Comments code - now fixed. Zinsco Panel. Saved from absoluteid.net. While the wiring inside an older panel may appear perfectly fine, I believe these panels should be replaced (better safe than sorry). Have one to sell? Eaton/Cutler Hammer CH8CS Loadcenter Cover. Free shipping for many products! SB15(20-30)C (Indoor) Mod.1 150A Max. Image not available. [Shown above]. I want to see the color and appearance of the circuit breakers. Can you tell me by the pictures [shown here] if mine is a ZINSCO™ electrical box that is unsafe? Also called a breaker box, electrical box or even a fuse box, the main function is to take electricity supplied by the utility and distribute it throughout the home to feed lights and receptacles. The deficiencies that became evident were serious enough to be considered both a fire and electrical shock risk. Or see circuit breaker labels matching those in the article above on this page. Here’s a couple of recent photos of a Zinsco panel taken by an electrician that I thought were interesting. Read Or Download The Diagram Pictures Diagram For FREE Diagram Zinsco at CROWDFUNDING.DEMO.AGRIYA.COM > can't reset breaker > posts picture of Zinsco panel – Harper - Reinstate Monica Dec 11 '18 at 16:00. The first Zinsco panels and breakers- labeled “Magnatrip”- (patent issued in 1950) had copper bus-bars and breaker clips. If you have one, you’ll want to call a pro as soon as possible to upgrade. Federal Pacific Electrical Panels and Zinsco Electrical Panels (also known as Zinsco Sylvania) were installed in new homes throughout entire neighborhoods from the mid-1950s to the early 1980s. Federal Pacific & Zinsco Panel Replacement Costs. Zinsco was a popular brand of electrical panel in the 1970's. We're in Ontario Canada, house was built sometime between very late 70's and very early 80's (no firm documentation). panel manufactured by Zinsco or Federal Pacific Electric (FPE). Federal Pacific Electrical Panels and Zinsco Electrical Panels (also known as Zinsco Sylvania) were installed in new homes throughout entire neighborhoods from the mid-1950s to the early 1980s. I'd also like to see. Image not available. Respectfully Daniel Friedman, Editor. This is a picture of a melted Zinsco breaker. The word Zinsco on the panel door tag, on panel labels or data tags (Zinsco panel label photo above). Residential main breaker panels are available in four sizes, 100 amps, 125 amps, 150 amps and 200 amps. Take a look at HISTORY of ZINSCO ELECTRICAL PANELS and thanks for the question, When was it determined that the Sylvania-Zinco electric panel were unsafe? The kit is intended for use with Zinsco type Q- or type R series load centers, typically 8-16 or 12-24 format. Also, many GTE-Sylvania or Sylvania panels are simply re-branded Zinsco panels or contain the problem Zinsco design. We deliver the best home inspections in your neighborhood.Our reputation is built on decades of honesty, integrity and excellent service to customers during one of their most important life decisions – buying or selling a home. 1. Try pushing it towards the panel center strip.Sometimes if a breaker has tripped it needs to be switched fully to OFF before it can be re-set to ON. First thing I have to say is that you should really consider a panel upgrade as soon as possible. "How to plan and install electric wiring for homes, farms, garages, shops," Montgomery Ward Co., 83-850. These electrical panels do not use the Zinsco or GTE-Sylvania-Zinsco electrical panel bus and breaker design. Panel Below is a picture of a Federal Pacific Electric panel. Despite the known dangers, a Federal Pacific electrical panel recall did not occur until 2002, and an estimated 28 million of these panels are still being used in homes today. What should you do if you find one of these PANELS? Divide the total wattage by 230, as per the NEC, for total amperage of 135.2173 (31,100 / 230 = 135.2173). Take care: Neither you nor I want to be roped into providing any guarantee, warranty, safety promises about your home - me in particluar as I don't know a thing about your home - since in the future, heaven forbid, when ANYTHING goes wrong that could be the subject of a future dispute. I have attached some pictures of the panel. Zinsco Circuit Breakers have been color coded to make it easier to identify, especially when the amperage on the handle is … Panel interlock kits for Bryant, Challenger, Crouse-Hinds, Cutler Hammer, Eaton, GE General Electric, Gould, GTE-Sylvania, ITE, Murray, Siemens, Square-D, Thomas & Betts *T&B), and Westinghouse. At IDENTIFY GTE SYLVANIA-ZINSCO PANELS we show the. - Sylvania BC 40200 using QBH circuit breakers, On 2020-03-14 Picture Information. While the wiring inside an older panel may appear perfectly fine, I believe these panels should be replaced (better safe than sorry). There is 4 1/4" between the bottom of the double-throw main 200amp, and the top of the 1st row of service breakers. Zinsco Circuit Breakers At Circuit Breaker Wholesale, we’re proud to stock hundreds of Zinsco Circuit Breakers. Photographs contributed to this website by Jim P. Simmons, Mr. Electric, Licensed Master Electrician, Photographs above & below provided courtesy of professional home inspectors - Anonymous. Above on this page are other clues that can be seen if your electrician removes the panel cover: a quick look for the unique Zinsco bus design. I am trying to sell a property in Tampa, FL, but buyer home inspector require me to replace the Sylvania Electric Panel "because is dangerous". Please notice the copper red bracket in the Picture. Home Decor. Thanks to our wide inventory of Zinsco … We educated ourselves pretty quick on aluminum wiring, and told the sellers they had to get an electrician to check it out, replace the panel, and remediate the wiring. and also INTERLOCK KITS vs TRANSFER SWITCHES. Certain components of the panel contain aluminum, The connection between the breakers and bus bar is not solid, Breakers may appear to be off, yet internally the panel may be conducting power. Download Attachment: Zinsco Line Taps .JPG. Square D QO Panel Deadfront Cover With Door 24 Space. Originals were mounted like this. Mod. There is another type of panel that looks, at first glance, like it might be missing a main breaker. Zinsco panels can generally be identified by a blue and silver "Zinsco" label inside the panel, and an embossed "Magnetrip" label at the top of the panel face. Circuit breakers come in several styles, including the standard single-pole breakers that serve 120-volt household circuits and double-pole breakers that take up two slots in a breaker box and serve 240-volt appliances. This is not a DIY project for most homeowners. What is between this panel and the meter? On 2020-01-21 by Sharon Anyways, here's a picture of the panel. We educated ourselves pretty quick on aluminum wiring, and told the sellers they had to get an electrician to check it out, replace the panel, and remediate the wiring. So I suspect you can find one of the companies who can provide the interlock kit for your older Sylvania panel. Again, here are the major issues with Zinsco Panels: If you know or suspect you may have a Zinsco brand panel, most experts in the field of electricity today recommend the panel be replaced. - Sylvania ML12(12-24)CG Panel is a Zinsco type, On 2020-01-22 by (mod) - detailed photo & taking measurements to try to replace the bus assembly of a Sylvania Electric Panel, Sharon I'll look around too but I'm afraid we may not find an interlock add-on for some older panels like this Sylvania Electric model. We deliver the best home inspections in your neighborhood. In fact, were I buying a home with a Zinsco panel, it would be the first thing I’d have replaced. Option1 – replace the Zinsco Sylvania panel interior bus assembly using a retrofit kit: The first section of this document OPTION #1 RETROFIT KIT describes how to replace Zinsco or Zinsco-type Sylvania Electric Panels in buildings using a retrofit kit provided by Eaton Corp., Cutler Hammer Products (E-CH): Option … Also you find the Sylvania electrical panel label showing the Sylvania Electric catalog numbers SMB20 (20-40)S Mod. Zinsco or Zinsco-Sylvania is the name given to a brand of electrical panel that was commonly installed up to the mid-1970’s. Production was halted when design flaws were discovered. This is a stupid question I know, but yesterday I had an extension cord running from my garage outside to weld. On 2020-09-22 by (mod) Below: a Sylvania Electric panel circuit breaker with a stab-clip buss connection that is different from the Sylvania-Zinsco circuit breaker designs discussed above on this page. Mouse over to Zoom-Click to enlarge. Free shipping. That's why one needs to look at more-technical details. Find many great new & used options and get the best deals for Zinsco 200 amp panel buss. These should also be replaced. I have a 125A Sylvania electrical subpanel in my house. See attached image. Please re-post the image if you can. Seeing as it is in the closet in guessing it's a sub panel so go with a square d home line for your next panel. Zinsco never did lose their U.L. Mouse over to Zoom-Click to enlarge. Above: a 1984 Sylvania Electrical panel in a Florida home. The homeowner reportedly heard a loud pop followed by a sizzle noise and a burning smell. This panel cover is listed a MLB20(20-40) and will handle 20 circuits with wide Type (Q,QC) breakers or 40 circuits with thin (Type RC-38) Measures 14.25" wide and 29" High. Zinsco Circuit Breakers have been color coded to make it easier to identify, especially when the amperage on the handle is … Most-likely this is not one of the problem Zinsco-Sylvania panels, but1. It would be helpful if you'd also post a photo of the circuit breakers in your panel. Well, maybe not. Apologies for the delay. Panels were known to fail, while still conducting power. I tagged along with the inspector and he told me the house (1973 build) had a Zinsco panel and aluminum wiring. If I had run accross the situation in your picture, I'm quite sure that I would have flipped off the breaker & tested the taps. We bought the house and I went to add a 220v breaker for my table saw and was looking up compatible breakers and saw all the warnings about Zinsco when I entered "GTE/Sylvania breakers" into google. It is certainly NOT a stupid question - lots of people run into confusion about which is the "ON" Position for circuit breakers as I'll detail here: Switches in positions 9-10 that is a 240V double pole breaker looks to be in the OFF position. So we know that the panel was rated to provide a maximum of 175 Amp 240VAC electrical service (though your service amapcity could be less). Then I realised the source of my problem was a blown fuse in the garage. Mar 6, 2020 - This is a picture of a melted/damaged Zinsco breaker. Are all Zinsco panels and circuit breakers under suspicion of failure? X. With an electrician's hourly rates at $40 to $100/hour and with the first hour costing $75 to $120, you can expect to spend between $400 and $800 for labor costs. We understand that hard-to-find and obsolete breakers and hardware can create a frustrating obstacle when it comes to getting your electrical system up and running. Sylvania, non-Zinsco circuit breaker & electrical panel identification guide: Here we provide text, labels, and equipment photographs used to help identify Sylvania electrical panels and circuit breakers. This panel is no longer manufactured new, though we do see some vendors selling new old stock. Melted Zinsco Breaker/Damage. This type of panel is configured such that it takes a maximum of 6 throws to shut all the power off. This circuit breaker may have been installed in a GTE-Sylvania electrical panel that did not use the Zinsco-design circuit breakers and/or may be of a different brand or manufacture. Zinsco Panel, Home Inspectors’ Bad news. Alpha & Omega Home Inspections, This 1969 Zinsco panel had breakers labeled UND LAB INC. if I read correctly. Try pushing it towards the panel center strip. The earliest Zinsco panel had buss bars mad of copper. In fact, were I buying a home with a Zinsco panel, it would be the first thing I’d have replaced. Explore. It has also been suggested that a listing by Underwriters Laboratories (UL) would never have been allowed had they been given correct data in testing. We do not recommend mere replacement of Zinsco circuit breakers themselves. Have one to sell? Eaton currently manufactures c/b for this panel, they are bolt-on, and the "new" type is QBH. - 200A Sylvania electrical panel in Ontario home. Production was halted when design flaws were discovered. This means the circuits are more likely to overheat or catch fire. Please notice the copper red bracket in the Picture. Below original Zinsco Feed Through with feed through mounting. Originals were mounted like this. One’s the SE with the cover open, next is a close up of the breakers (look at the 125 A main): Here’s the 125 A breaker removed: I understand the home is getting a completely new SE panel. Seeing as it is in the closet in guessing it's a sub panel so go with a square d home line for your next panel. I was checking your information and look like the panel is not a Zinsco one but I will like a lot more comfortable if you can help me to confirm this. Home Maintenance. InspectAPedia tolerates no conflicts of interest. by (mod) A special kind of circuit breaker is the tandem breaker, which is designed to allow two 120-volt circuits to be fit into a single slot in the circuit breaker box. The switched melt into the panel rather than tripping and cutting off power. Can anyone tell me about this breaker panel? A large label on the door shows Cat No: ML12(12-24)CG (Indoor) - Mod 2. Hickory Grove, SC for his photos of a Kearney electrical panel. Interrior from box Z2020 at the best online prices at eBay! Like FPE panels they had problems with contact to the bus bar and latter they became known as Sylvania about the early 70’s. Electrical panel interior access should be by a licensed and trained electrician. This type of Service Panel is called a Split-Bus Panel. And don't hesitate to ask follow-up questions as needed. Like FPE panels they had problems with contact to the bus bar and latter they became known as Sylvania about the early 70’s. This is a 120/240 VAC rainproof type 3R panel enclosure. In 2012, the city of Napa, Calif., actually required replacement of Zinsco … Zinsco or Zinsco-Sylvania is the name given to a brand of electrical panel that was commonly installed up to the mid-1970’s. Thanks in advance! These electrical panels do not use the Zinsco or GTE-Sylvania-Zinsco electrical panel bus and breaker design. 1-Pole Federal Pacific Stab-Lok Type NA Replacement Circuit Breaker Connecticut Electric manufactures new high Connecticut Electric manufactures new high quality replacement circuit breakers for Stab-Lok load centers that accept NA style circuit breakers. We have no relationship with advertisers, products, or services discussed at this website. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. Pretty confident its not one of the Zinsco panels, so not looking to replace the panel. New VPKUBIF Thick 20 Amp 1/2 in. Currently there is a double breaker 60amp on the bottom left, we plan on getting that moved to a "pony panel" as its the power that goes out to the barn electrical panel, and that would free up the space for a double breaker 30amp for the generator plug. "Simplified Electrical Wiring," Sears, Roebuck and Co., 15705 (F5428) Rev.

Drexel College Of Medicine Supplemental Application, Ni No Kuni 2 Swift Solutions Quests, 1986 Dodgers Roster, Monokuma Cosplay Ideas, Media Specialist Certification Online, Fresher Graphic Designer Jobs In Kolkata, Individual Cricket Coaching, How To Recharge Puff Bar Plus, Garnier Pure Charcoal Black Tissue Mask Review, Madden Cover Dimensions, Dermatologist Quad Cities, James Lightfoot Obituary Florida,